Abstract
We investigated factors involved in achieving a single gas bubble following intravitreal gas injection during surgery for retinal detachment. A simple mathematical model of gas bubble dynamics within the eye was developed. The model indicates that the speed at which the bubble rises within the eye is proportional to the radius of the bubble. The flow rate required to maintain a single bubble increases as a power function of the bubble radius. In conclusion, the speed of injection is of paramount importance in the attainment of a single gas bubble.
Similar content being viewed by others
Article PDF
References
Norton EWD . Intraocular gas in the management of selected retinal detachments. Ophthalmology 1973;77:85–98.
Gilbert C, McLeod D . D-ACE sequence for selected bullous retinal detachments. Br J Ophthalmol 1985;69:733–6.
Hilton GF, Grizzard WS . Pneumatic retinopexy: a two step outpatient operation without conjunctival incision. Ophthalmology 1986;93:626–41.
Massey BS . Mechanics of fluids, 6th edn. London: Chapman and Hall, 1989.
Kawano S, Honda Y, Negi A . Effects of biological stimuli on the viscosity of the vitreous. Acta Ophthalmol (Copenh) 1982;60:977–91.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Aylward, G., Lyons, C. The importance of injection rate in achieving a single intraocular gas bubble. Eye 10, 590–592 (1996). https://doi.org/10.1038/eye.1996.135