Abstract
Quantum measurements not only extract information from a system but also alter its state. Although the outcome of the measurement is probabilistic, the backaction imparted on the measured system is accurately described by quantum theory1,2,3. Therefore, quantum measurements can be exploited for manipulating quantum systems without the need for control fields4,5,6. We demonstrate measurement-only state manipulation on a nuclear spin qubit in diamond by adaptive partial measurements. We implement the partial measurement via tunable correlation with an electron ancilla qubit and subsequent ancilla readout7,8. We vary the measurement strength to observe controlled wavefunction collapse and find post-selected quantum weak values8,9,10. By combining a novel quantum non-demolition readout on the ancilla with real-time adaptation of the measurement strength we realize steering of the nuclear spin to a target state by measurements alone. Besides being of fundamental interest, adaptive measurements can improve metrology applications11,12,13 and are key to measurement-based quantum computing14,15.
Similar content being viewed by others
Main
Measurements play a unique role in quantum mechanics and in quantum information processing. The backaction of a measurement can be used for state initialization16, generation of entanglement between non-interacting systems17,18, and for qubit error detection19. These measurement-based applications require either post-selection or real-time feedback, as the outcome of a measurement is inherently probabilistic. Recent experiments achieved quantum feedback control on a single quantum system18,20,21,22 by performing coherent control operations conditioned on a measurement outcome.
Here, we realize real-time adaptive measurements and exploit these in a proof-of-principle demonstration of measurement-only quantum feedback. Our protocol makes use of partial measurements that balance the information gain and the measurement backaction by varying the measurement strength. We accurately control the measurement strength and the corresponding backaction in a two-qubit system by tuning the amount of (quantum) correlation between the system qubit and an ancilla qubit, followed by projective readout of the ancilla7,8. In general, the backaction of sequential partial measurements leads to a random walk1,2,3 but, by incorporating feedback, multiple measurements can direct the trajectory of a qubit towards a desired state4,5,6. Real-time adaptive measurements are a key ingredient for quantum protocols such as one-way quantum computing14,15 and Heisenberg-limited phase estimation11,12,13.
We implement the adaptive partial measurements in a nitrogen vacancy centre in synthetic diamond. We define the system qubit by the nuclear spin of the nitrogen vacancy host nitrogen(|↓〉 : mI = 0, |↑〉 : mI = −1), and the ancilla qubit by the nitrogen vacancy electron spin (|0〉 : mS = 0, |1〉 : mS = −1) (Fig. 1a). The ancilla is initialized and read out in a single shot with high fidelity using spin-selective optical transitions16. We perform single-qubit operations on the ancilla by applying microwave frequency pulses to an on-chip stripline.
We realize the variable-strength measurement by correlating the system qubit with the ancilla through a controlled-phase-type gate (Fig. 1b) that exploits the hyperfine interaction, which (neglecting small off-diagonal terms) has the form (with A = −2π × 2.184 ± 0.002 MHz and , the three-level Pauli z-operators for the electron, nuclear spin respectively). During free evolution, the ancilla qubit precession is conditional on the state of the system qubit. We choose the rotating frame such that the ancilla rotates clockwise (anti-clockwise) around the z-axis if the system qubit is in |↑〉 (|↓〉) and vary the interaction time τ. For τ = 0, there is no correlation between the ancilla and the system, whereas for τ = π/A, corresponding to the rotation angle θ = 90° , the two are maximally correlated. A subsequent rotation and projective readout of the ancilla then implements a measurement of the system qubit, with a measurement strength that can be accurately tuned by controlling the interaction time τ. A mathematical derivation can be found in the Supplementary Information.
We investigate the measurement-induced backaction by preparing an initial state of the system (|↑〉, |x〉 and |y〉) and performing a partial measurement with strength θ, followed by state tomography (Fig. 2). First, we neglect the outcome of the partial measurement, which is mathematically equivalent to taking the trace over the state of the ancilla qubit. In this case the backaction is equivalent to pure dephasing, as can be seen by a measured reduction of the length of the Bloch vector (Fig. 2b). Next, we condition the tomography on the ancilla measurement yielding state |0〉 (Fig. 2c). We observe that for a weak measurement (θ = 5°), the system is almost unaffected, whereas for increasing measurement strength it receives a stronger kick towards |↑〉 (Fig. 2c). Crucially, we find that the length of the Bloch vector is preserved in this process, as expected for an initially pure state. This shows that the partial collapse is equivalent to a qubit rotation that is conditional on the measurement strength and outcome and on the initial state. By performing quantum process tomography, we find that both measurement processes agree well with the theoretical prediction (the process fidelities are 0.986 ± 0.004 and 0.94 ± 0.01 for the unconditional and conditional process, respectively; see Supplementary Information).
By combining a partial measurement with post-selection on the outcome of a subsequent projective measurement, we can measure the generalized weak value f〈Iz〉 (conditioned average of contextual values23, see Supplementary Information) of the nuclear spin in the z-basis. In the limit of zero measurement strength (θ = 0°), this quantity approximates the weak value9W = 〈ψf|Iz|ψi〉/〈ψf|ψi〉, where ψi(ψf) is the initial (final) state of the nucleus and from here we define Iz as the Pauli z-operator reduced to a two-level system with eigenvalues +1 and −1. By post-selecting only on the final states having small overlap with the initial state, f〈Iz〉 can be greatly amplified to values that lie outside the range of eigenvalues of the measured observable. As shown in Fig. 2d, by sweeping the angle between the initial and final states we observe up to tenfold amplification (f〈Iz〉 = 10 ± 3) compared to the maximum eigenvalue of Iz (+1). This amplification is the highest reported for a solid-state system to date8. As predicted24 , we observe that values of f〈Iz〉 lying outside of the range of eigenvalues of Iz can be found for any finite measurement strength.
Using the partial measurements for measurement-based feedback requires reading out the ancilla without perturbing the system qubit. In our experiment the system qubit can dephase during ancilla readout both through a spin-flip of the electron in the course of optical excitation (Fig. 3b) and as a result of the difference in the effective nuclear g-factor in the electronic ground- and optically excited state25. Note that for the characterization of a single partial measurement (Fig. 2) we circumvent this dephasing by interchanging the basis rotation pulses for tomography and the ancilla readout; this interchange is not possible for real-time adaptive measurements.
To mitigate the nuclear dephasing during ancilla readout we reduce the ancilla spin-flip probability using a dynamical-stop readout technique. We partition the optical excitation time in short (1 μs) intervals and we stop the excitation laser as soon as a photon is detected, or after a predetermined maximum readout time when no photon is detected (Fig. 3a). This reduces redundant excitations without compromising the readout fidelity. In Fig. 3b we show the correspondence between pre- and post-measurement states for the two eigenstates of the ancilla. For the state |0〉 the dynamical-stop readout increases the fidelity (F = 〈ψi|ρm|ψi〉, where ρm is the density matrix of the system after the ancilla readout) from 0.18 ± 0.02 to 0.86 ± 0.02. The latter fidelity is solely limited by the cases where the spin flipped before a photon was detected: we find F = 1.00 ± 0.02 for the cases in which a photon was detected. As expected, the fidelity is high (F = 0.996 ± 0.006) for input state |1〉, as this state is unaffected by the excitation laser. The dynamical-stop technique thus implements a quantum non-demolition measurement of the ancilla electron spin with an average fidelity of 0.93 ± 0.01 for the post-measurement state.
The dynamical-stop readout of the ancilla significantly reduces the dephasing of the nuclear spin qubit during measurement, as shown in Fig. 3c. Starting with the nuclear spin in state, a conventional readout of the ancilla completely dephases the nuclear spin, leading to a state fidelity with respect to |x〉 of 0.5. In contrast, the fidelity of the dynamical-stop readout saturates to 0.615 ± 0.002 (probably limited by changes in the effective g-factor of the nuclear spin). The dynamical-stop readout thus leaves the system in a coherent post-measurement state that can be used in a real-time feedback protocol.
Preserving coherence of the post-measurement state enables a proof-of-principle realization of measurement-only control, by implementing sequential measurements and tuning the strength of the second measurement in real time conditioned on the outcome of the first measurement (Fig. 4a). We choose as our target the creation of the state |ψ〉 = cos(π/4 + θ1/2)|↓〉 + cos(π/4 − θ1/2)|↑〉 from initial state |x〉 using only partial measurements of . The first measurement with strength θ1 will prepare either the desired state, or the state |ψwrong〉 = cos(π/4 − θ1/2)|↓〉+cos(π/4 + θ1/2)|↑〉, each with probability 0.5. We adapt the strength of the second measurement θ2 according to the outcome of the first measurement: we set θ2 = 0 if the first measurement directly yielded the target state, but if the ‘wrong’ outcome was obtained we set the measurement strength to
such that the second measurement will probabilistically rotate the qubit to the target state (see Supplementary Information). The total success probability of this two-step protocol is psuc = 1/2(1 + cosθ1) and a successful event is heralded by the outcome of the ancilla readout. In principle the protocol can be made fully deterministic5 by incorporating a reset in the form of a projective measurement along the x-axis.
To find the improvement achieved by the feedback, we first compare the success probability of our adaptive measurement protocol to the success probability for a single measurement (Fig. 4b, bottom panel). The success probability clearly increases with the adaptive protocol and is proportional to the readout fidelity of the |0〉 state of the ancilla, which is maximum for readout times >25 μs. The fidelity of the final state (Fig. 4b, upper panel) is limited by the remaining dephasing of the system during readout of the ancilla, as shown in Fig. 3b. This constitutes the trade-off between success probability and state fidelity.
We show that the increase in success probability is non-trivial by comparing the final state fidelity with and without feedback (Fig. 4b, upper panel). In principle the success probability can be increased in the absence of feedback by accepting a certain number of false measurement outcomes at the cost of a reduced fidelity. We calculate the maximum fidelity that can be achieved in this way by performing only the first measurement and increasing the success probability to that of the adaptive protocol using post-selection (grey line in Fig. 4b, upper panel). We find that the measured state fidelity in the adaptive protocol is above this bound (Fig. 4b, green area), which indicates that the adaptive measurement indeed successfully corrects the kickback from the first measurement, thus yielding a clear advantage over open-loop protocols.
We note that, in contrast to pioneering adaptive measurement experiments on photons that only used experimental runs in which a photon was detected at each measurement stage15, our protocol is fully deterministic in the sense that the partial measurement always yields an answer. In particular, the data in Fig. 4 includes all experimental runs and thus no post-selection is performed, as desired for future applications in metrology and quantum computing.
The performance of the protocol can be further improved by increasing the ancilla readout fidelity (either by improving the collection efficiency or reducing spin-flip probability) and by further reducing the dephasing of the system during readout. A particularly promising route is to use nuclear spins farther away from the nitrogen vacancy centre (for example carbon-13 spins) that have much smaller hyperfine couplings26,27,28 and are more robust against changes in the orbital state of the electron spin.
Our work is the first experimental exploration of a fundamental concept of ‘control-free control’4,5,6. Furthermore, the use of adaptive measurements as presented here can increase the performance of spin-based magnetometers11,12. Finally, our results can be combined with recently demonstrated methods for generating entanglement between separate nitrogen vacancy centre spins29,30. Taken together, these techniques form the core capability required for one-way quantum computing, where quantum algorithms are executed by sequential adaptive measurements on a large entangled ‘cluster’ state14,15.
Methods
Sample and set-up.
We use a naturally-occurring nitrogen-vacancy centre in high-purity type IIa chemical vapour deposition diamond, with a 〈111〉-crystal orientation obtained by cleaving and polishing a 〈100〉-substrate. Experiments are performed in a bath cryostat, at a temperature of 4.2 K, with an applied magnetic field of 17 G. Working at low temperature, we can perform efficient electron spin initialization (F = 0.983 ± 0.006) and single-shot readout (the fidelity is 0.853 ± 0.005 for mS = 0 and 0.986 ± 0.002 for mS = −1) by spin-resolved optical excitation16. Initialization of the nuclear spin is done by measurement17, with fidelity 0.95 ± 0.02. Single-qubit operations can be performed with high accuracy using microwave (for the electron) and radio-frequency (for the nucleus) pulses applied to the gold stripline. Note that the single-qubit operations on the nucleus are only used for state preparation and tomography, but not in the feedback protocol. The dephasing time T2∗ is (7.8 ± 0.2) ms for the nuclear spin and (1.35 ± 0.03) μs for the electron spin.
Error analysis.
The 68% confidence intervals are calculated through error propagation, taking into account the statistical error of the measurement, as well as the uncertainty in the correction for readout and initialization infidelity.
References
Guerlin, C. et al. Progressive field-state collapse and quantum non-demolition photon counting. Nature 448, 889–893 (2007).
Hatridge, M. et al. Quantum back-action of an individual variable-strength measurement. Science 339, 178–181 (2013).
Murch, K. W. et al. Observing single quantum trajectories of a superconducting quantum bit. Nature 502, 211–214 (2013).
Jordan, A. N. & Korotkov, A. N. Qubit feedback and control with kicked quantum nondemolition measurements: A quantum Bayesian approach. Phys. Rev. B 74, 085307 (2006).
Ashhab, S. & Nori, F. Control-free control: Manipulating a quantum system using only a limited set of measurements. Phys. Rev. A 82, 062103 (2010).
Wiseman, H. M. Quantum control: Squinting at quantum systems. Nature 470, 178–179 (2010).
Brun, T. A., Diosi, L. & Strunz, W.T. Test of weak measurement on a two- or three-qubit computer. Phys. Rev. A 77, 032101 (2008).
Groen, J. P. et al. Partial-measurement backaction and non-classical weak values in a superconducting circuit. Phys. Rev. Lett. 111, 090506 (2013).
Aharonov, Y., Albert, D. Z. & Vaidman, L. How the result of a measurement of a component of the spin of a spin-1/2 particle can turn out to be 100. Phys. Rev. Lett. 60, 1351 (1988).
Pryde, G. J. et al. Measurement of quantum weak values of photon polarization. Phys. Rev. Lett. 94, 220405 (2005).
Cappellaro, P. et al. Spin-bath narrowing with adaptive parameter estimation. Phys. Rev. A 85, 030301(R) (2012).
Higgins, B. L. et al. Entanglement-free Heisenberg-limited phase estimation. Nature 450, 393–396 (2007).
Napolitano, M. et al. Interaction-based quantum metrology showing scaling beyond the Heisenberg limit. Nature 471, 486–489 (2011).
Raussendorf, R. & Briegel, H. J. A one-way quantum computer. Phys. Rev. Lett. 86, 5188–5191 (2001).
Prevedel, R. et al. High-speed linear optics quantum computing using active feed-forward. Nature 445, 65–69 (2007).
Robledo, L. et al. High-fidelity projective read-out of a solid-state spin quantum register. Nature 477, 574–578 (2011).
Pfaff, W. et al. Demonstration of entanglement-by-measurement of solid-state qubits. Nature Phys. 9, 29–33 (2013).
Ristè, D et al. Deterministic entanglement of superconducting qubits by parity measurement and feedback. Nature 502, 350–354 (2013).
Chiaverini, J. et al. Realization of quantum error correction. Nature 432, 602–605 (2004).
Gillett, G. C. et al. Experimental feedback control of quantum systems using weak measurements. Phys. Rev. Lett. 104, 080503 (2010).
Sayrin, C. et al. Real-time quantum feedback prepares and stabilizes photon number states. Nature 477, 73–77 (2011).
Vijay, R. et al. Stabilizing Rabi oscillations in a superconducting qubit using quantum feedback. Nature 490, 77–80 (2012).
Dressel, J., Agarwal, S. & Jordan, A. N. Contextual values of observables in quantum measurements. Phys. Rev. Lett. 104, 240401 (2010).
Williams, N. S. & Jordan, A. N. Weak values and the Leggett–Garg inequality in solid-state qubits. Phys. Rev. Lett. 100, 026804 (2008).
Jiang, L. et al. Coherence of an optically illuminated single nuclear spin qubit. Phys. Rev. Lett. 100, 073001 (2008).
Zhao, N. et al. Sensing single remote nuclear spins. Nature Nanotech. 7, 657–662 (2012).
Taminiau, T.H. et al. Detection and control of individual nuclear spins using a weakly coupled electron spin. Phys. Rev. Lett. 109, 137602 (2012).
Kolkowitz, S. et al. Sensing distant nuclear spins with a single electron spin. Phys. Rev. Lett. 109, 137601 (2012).
Bernien, H. et al. Heralded entanglement between solid-state qubits separated by three meters. Nature 497, 86 (2013).
Dolde, F. et al. Room-temperature entanglement between single defect spins in diamond. Nature Phys. 9, 139–143 (2013).
Acknowledgements
We thank L. DiCarlo, G. De Lange and L. Vandersypen for helpful discussions and comments, and R. N. Schouten and M. J. Tiggelman for technical assistance. We acknowledge support from the Dutch Organization for Fundamental Research on Matter (FOM), the DARPA QuASAR programme, the EU DIAMANT and S3NANO programmes and the European Research Council through a Starting Grant. Work at the Ames Laboratory was supported by the US Department of Energy Basic Energy Sciences under contract no. DE-AC02-07CH11358.
Author information
Authors and Affiliations
Contributions
M.S.B., C.B., V.V.D. and R.H. designed the experiment. M.S.B. and C.B. performed the experiments and analysed the results. M.L.M. and D.J.T. designed and carried out synthesis of (111) engineered chemical vapour deposition diamond material. M.S.B., C.B. and R.H. wrote the manuscript. All authors discussed the results and commented on the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Supplementary information
Supplementary Information
Supplementary Information (PDF 2009 kb)
Rights and permissions
About this article
Cite this article
Blok, M., Bonato, C., Markham, M. et al. Manipulating a qubit through the backaction of sequential partial measurements and real-time feedback. Nature Phys 10, 189–193 (2014). https://doi.org/10.1038/nphys2881
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/nphys2881
This article is cited by
-
Learning quantum systems
Nature Reviews Physics (2023)
-
Effect of partial-collapse measurement on relativistic quantum Bayesian game under decoherence
Quantum Information Processing (2021)
-
High-resolution spectroscopy of single nuclear spins via sequential weak measurements
Nature Communications (2019)
-
Tracking the precession of single nuclear spins by weak measurements
Nature (2019)
-
Effect of partial-collapse measurement on quantum Stackelberg duopoly game in noninertial frame
Quantum Information Processing (2019)