A wearable cardioverter–defibrillator does not significantly reduce the risk of arrhythmic death after a myocardial infarction (MI), according to the results of the VEST study. Implantable cardioverter–defibrillators are contraindicated until 40–90 days after MI, so a wearable defibrillator might reduce the rate of sudden death during this high-risk period. A total of 2,302 patients with acute MI and an ejection fraction ≤35% were randomly assigned (2:1) to receive the wearable cardioverter–defibrillator LifeVest (ZOLL Medical) plus guideline-directed therapy or guideline-directed therapy alone. Participants in the device group wore the LifeVest for a median of 18 h per day. The rate of the primary end point (arrhythmic death) was 1.6% in the device group and 2.4% in the control group (relative risk (RR) 0.67, 95% CI 0.37–1.21, P = 0.18). All-cause mortality was 3.1% and 4.9% in each group, respectively (RR 0.64), and nonarrhythmic death occurred in 1.4% and 2.2% of patients in each group, respectively (RR 0.63). In the device group, 1.3% received an appropriate shock, 0.6% received an inappropriate shock, and 25% of the 48 patients who died were wearing the LifeVest at the time of death.
References
Original article
Olgin, J. E. et al. Wearable cardioverter–defibrillator after myocardial infarction. N. Engl. J. Med. 379, 1205–1215 (2018)