Background

Molecular imaging of breast cancer through the use of [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET) is commonly used for tumour staging and assessment of therapy response. However, it is limited by its poor differentiation of malignant and benign lesions [1], varied sensitivity and inability to pick up certain histologic subtypes [2]. There is therefore a need for alternative molecular imaging tracers that can address limitations such as these. In addition, new drugs are being developed to target breast cancer metabolism, including amino acid and mitochondrial metabolism, and ways to assess their biological activity and stratify patients are needed [3]. Amino acid uptake is upregulated in breast cancer [4], therefore synthetic amino acid analogues may be a useful tool in molecular imaging of this disease [5]. 18F-Fluciclovine (anti-1-amino-3-fluorocyclobutane-1-carboxylic acid or FACBC) is a synthetic amino acid PET radiotracer already licensed for use in patients with biochemically recurrent prostate cancer [6, 7], and its utility for imaging breast cancer is currently under investigation [5, 8, 9].

Quantitative imaging techniques in PET, looking specifically at the distribution of tracer uptake over time, can provide information that reflects the true underlying physiology within the regions of interest [10,11,12]. Furthermore, using kinetic modelling, quantitative estimates of blood flow into the tumour, 18F-fluciclovine transport and intracellular containment can be extracted, as opposed to the commonly used semi-quantitative parameter SUV (standardized uptake value).

We conducted a ‘window of opportunity’ clinical study (FRONTIER) in which we recruited 39 female patients with treatment-naive primary breast cancer. Participants underwent an 18F-fluciclovine PET-computed tomography (CT) scan shortly after diagnosis and prior to definitive treatment. The primary objective was to characterise 18F-fluciclovine uptake using PET imaging for different breast cancer receptor subtypes. Exploratory objectives were to determine the most suitable kinetic model to describe 18F-fluciclovine uptake in patients with invasive breast cancer for the primary tumour and assess differences in tracer kinetics and SUV between tumour receptor subtypes. We also assessed whether there was a relationship between 18F-fluciclovine tumour uptake and three surrogate markers of clinical outcome in breast cancer that have previously been shown to correlate with breast tumour FDG uptake: grade, tumour Ki-67 expression and the neutrophil–lymphocyte ratio (NLR) [13, 14]. Ki-67 is a nuclear protein present in all active phases of the cell cycle, except the G0 phase, and is a well-validated measure of breast cancer proliferation, prognosis and response to therapy [15]. We hypothesised that tumours with greater rates of cell proliferation and hence greater anabolic macromolecular requirements would take up 18F-fluciclovine to a greater degree. The NLR has been shown to independently associate with increased mortality in breast cancer [16] and correlate with FDG uptake [14]. We hypothesised that tumours with higher NLR would take up 18F-fluciclovine to a greater degree.

In preclinical models, metformin has been shown to indirectly stimulate glutamine uptake into tumour cells as a consequence of inhibition of electron transport chain function in tumour mitochondria [17]. Therefore, a comparison of tumour uptake and kinetics in those patients who were and were not taking metformin was also carried out to assess the potential for this tracer to describe the metabolic response to anti-mitochondrial cancer therapies.

Methods

Patient selection

Thirty-nine female patients (age > 40 years) with biopsy-proven invasive breast cancer that measured 1.5 cm or more were recruited for the study between March 2017 and October 2018. Exclusion criteria were current pregnancy or breast feeding, multifocal breast cancer, prior treatment for breast cancer and participation in another investigational clinical study within 4 weeks prior to enrolment. Data were also collected describing patient demographics, medical history, tumour size (through ultrasound, mammography or MRI imaging), whether taking metformin, and standard of care breast histology to identify type, grade and receptor status. Receptor status was categorised into three distinct groups: oestrogen receptor positive only (ER+), human epidermal growth factor receptor positive (HER2+) and triple receptor negative (TN). Determination of receptor status was carried out using immunohistochemistry by the Cellular Pathology Laboratory at the John Radcliffe Hospital, Oxford University Hospitals NHS Trust to standardised protocols as part of routine clinical care. Oestrogen receptor Allred score of 2/8 or less was considered negative. For HER2 a score of 3+ on immunohistochemistry was considered positive, and if scored borderline (2+), HER2 in situ hybridisation testing was used as per current UK guidance [18]. The study was prospectively approved by the Oxford A Research Ethics Committee and registered with ClinicalTrials.gov identifier: NCT03036943. All patients involved gave written informed consent.

PET/CT imaging

Patients were imaged supine with their arms by their side using a Discovery 710 PET/CT scanner (GE Healthcare). They were injected with 370 MBq (±10%) of 18F-fluciclovine 30 s into the 20 min dynamic list-mode PET acquisition, which was centred over the breasts. Prior to each PET acquisition, a CT scan was performed for localisation and PET attenuation correction. PET data were reconstructed using a time-of-flight ordered subset expectation maximisation algorithm (VPFX, GE Healthcare) with a standard 6.4 mm Gaussian filter applied post reconstruction. The data were binned into two parallel time sequences, S1 (1 × 30 s, 12 ×  5 s, 6 × 10 s, 5 × 30 s, 10 × 60 s, 1 × 300 s) and S2 (1 × 30 s, 60 × 1 s, 12 × 10 s, 3 × 30 s, 10 × 60 s, 1 × 300 s), and the acquisition was also binned into four 5-min frames. The first 5-min frame will include rapid changes in tracer uptake following injection.

Primary tumours were outlined on the PET/CT images by an experienced radiologist. Cylindrical blood volumes of a diameter of 10 mm were generated within the central part of the descending aorta on at least five consecutive axial PET slices. PET sequences S1 and S2 were then used to produce time–activity curves (TACs) within the volume of interests, representing tracer uptake in the tumours/lymph nodes and blood, respectively. Kinetic analysis was performed on TACs obtained from primary tumours; lymph nodes were excluded due to their size.

Static analysis

18F-Fluciclovine uptake in tumours was measured for each 5-min time interval. SUVmax and SUVpeak were calculated using Hermes Hybrid Viewer (Hermes Medical Solutions AB) for each interval, in order to determine which time period demonstrated the highest level of uptake. The time interval in which peak uptake was seen was used for the semi-quantitative measurements of SUVmax and SUVpeak in primary tumours. The location of the SUVpeak volume was independently found for each time interval [19]. Example images of 18F-fluciclovine uptake in the time interval 5–10 min post injection are shown in Fig. 1. The liver and pancreas demonstrate high physiological 18F-fluciclovine uptake.

Fig. 1: Summed 5- to 10-min dynamic 18F-fluciclovine PET and fused PET/CT images of a patient with oestrogen receptor-positive IDC.
figure 1

The primary tumour is indicated by the arrows in the axial plane of the fused PET/CT images.

Kinetic analysis

To analyse the dynamic PET data, compartmental modelling was used. This allows the tracer uptake to be mathematically represented via a series of linear compartments; Supplementary Fig. 1 shows diagrams representing one- and two-tissue reversible compartmental models. As 18F-fluciclovine uptake is considered to be a reversible process and is not metabolised within cells [6], these were the models that were chosen to fit the time courses of tracer uptake. All kinetic analysis was carried out using PMOD software (version 3.9, PMOD Technologies LLC). Image-derived input functions were obtained using the decay-corrected blood TACs; linear interpolation was then used to fit curves to the data points.

Mathematical models of one- and two-tissue reversible compartmental models (named 1C2K and 2C4K, respectively) were fitted to 38 breast tumour TACs (one TAC was excluded due to patient movement). This was done by minimising the weighted sum of squares between the model fit and the measured TACs to achieve optimised fitting parameters [20]. This was carried out using the Levenberg–Marquardt algorithm

$${{SS}} = \mathop {\sum}\limits_{i = 1}^N {w_i\left( {C_{{PET}}\left( {t_i} \right) - C_{{model}}\left( {t_i} \right)} \right)^2}$$

where \(C_{{{{{\mathrm{PET}}}}}}\left( {t_i} \right)\) and \(C_{{{{{\mathrm{model}}}}}}\left( {t_i} \right)\) are the imaged and modelled activity concentrations at time \(t_i\) (the midpoint of the ith time frame) and \(w_i\) is the relative weighting factor calculated as

$$w_i = \frac{{\Delta t_ie^{ - \lambda t_i}}}{{C_{{{{{\mathrm{PET}}}}}}\left( {t_i} \right)}}$$

where \(\Delta t_i\) is the length of the ith frame and λ is the decay constant for 18F; the methodology is as previously published [13]. The volume of distribution (for the 1C2K model or first compartment for the 2C4K model) was calculated as K1/k2.

To ensure global best fits, model fitting was initiated from 200 random starting sets of values. These starting values were suitably constrained (vB 0.1–100%, K1 < 4 mL/min/mL, k2,3,4 < 4 min−1) to ensure appropriate model fitting parameters. The fits were also visually checked within PMOD.

Assessment of model fit

To determine whether the tracer uptake was adequately described by a particular model, the Wald–Wolfwitz runs test was used. Information criterion testing (Akaike and Bayesian) were also carried out for each model fit, to quantitatively assess how well the model describes the measured data. Further details on these statistical testing methods are described by McGowan et al. [21].

The precision of kinetic parameters from these fits was determined via Monte Carlo simulations: 1C2K and 2C4K model fits to the 38 patient TACs (and corresponding rate constants) were taken as ground truths (one TAC was excluded due to patient movement). A set of 1000 simulated noisy TACs were then generated (as described by McGowan et al. [21] from these ground truth TACs and fitted using both 1C2K and 2C4K models). For each ground truth TAC, average kinetic parameter values were calculated from fits to the 1000 simulated TACs and used alongside the ground truth parameter values to establish individual bias and uncertainty estimates on those values. These individual estimates were then combined to give the overall mean bias (MB) and variance of bias values (σB). The mean variance (σP) was calculated for each parameter as the average of the parameter variances obtained from the fits to the simulated TACs. σB and σP values were then combined in quadrature to give an overall uncertainty value σT.

$$\sigma {{{T}}} = (\sigma {{{B}}}^2 + \sigma {{{P}}}^2)^{1/2}$$

Clinical correlations

Tumour specimens were either sampled at the surgery or by ultrasound-guided core biopsy (diagnostic sample, if no suitable material at surgery was available). Following prompt fixation and processing of paraffin blocks, tumours were graded 1, 2 or 3 using the semi-quantitative Nottingham grading system [22] by the Cellular Pathology Laboratory at the John Radcliffe Hospital, Oxford University Hospitals NHS Trust to standardised protocols as part of routine clinical care. Staining for Ki-67 (mouse anti-Ki-67 monoclonal antibody, Dako) was performed on a Leica Bond-max autostainer in the Translational Histopathology Laboratory, Department of Pharmacology, University of Oxford. For Ki-67, the percentage of tumour cells with nuclear staining in at least three separate areas of a section were assessed with a minimum of 100 cells counted in each area and the mean was taken separately by two board-accredited pathologists.

The NLR was derived by simply dividing the absolute neutrophil count by the absolute lymphocyte count from a full blood count taken prior to tumour sample collection (Haematology Laboratory at the John Radcliffe Hospital, Oxford University Hospitals NHS Trust).

Statistical analysis

Correlations between static SUV parameters and kinetic parameters were assessed and unpaired two-tailed t tests were used to compare mean 18F-fluciclovine uptake across primary tumours for both SUV and kinetic parameters (K1, k2 and the volume of distribution, Vd). Paired two-tailed t tests were used to compare the means of tumour SUVpeak and SUVmax across the four 5-min time intervals. Analysis of variance testing was used to compare means of SUV and kinetic parameters against several clinical parameters, including tumour receptor subtypes, tumour grades and patients taking metformin. Pearson’s correlation coefficient was used to investigate correlations between PET parameters with Ki-67 and NLR. P values were considered to be statistically significant if <0.05.

Results

Quality of compartment fits to 18F-fluciclovine uptake

A detailed breakdown of patient and tumour characteristics are shown in Table 1. Of the eight HER2+ patients, five were ER+ and three ER−. The results from the runs test for the 1C2K and 2C4K compartment models are shown in Table 2. These are shown alongside summed Akaike information criterion (AIC) and Bayesian information criterion (BIC) values for the different models as well as the number of TACs for which each model scored lowest. Fits of the 2C4K model passed the runs test for 31 out of the 38 TACs and had lower total AIC and BIC scores than the 1C2K model. The 1C2K model had an overall higher number of TACs that demonstrated lower AIC and BIC values. Figure 2 shows 1C2K and 2C4K model fits in an example patient TAC and Supplementary Fig. 2 shows the corresponding Logan plot for this patient TAC, which supports the suitability of using a reversible compartment model.

Table 1 Patient and tumour characteristics and their corresponding n values.
Table 2 Summary of runs-test results and summed AIC and BIC scores for all TACs to which compartmental models were fitted (n = 38).
Fig. 2: Graphical representation of the time course of tumour tracer uptake in an example patient in the study.
figure 2

One- and two-tissue compartment models have been fitted to the tracer uptake in the tumour.

Table 3 shows the result of the statistical simulations whereby fits of the 1C2K and 2C4K to measured TACs were used to represent ground truths. The parameter values demonstrate that when 1C2K model fits were used to represent ground truth, 1C2K fits to simulated data had lower MBs and uncertainties than 2C4K fits. For ground truths represented by 2C4K model fits, 1C2K fits to simulated data generally had lower biases and variances than 2C4K fits. Due to the higher accuracy of kinetic parameters in the 1C2K model, this is considered the most appropriate to use to describe 18F-fluciclovine uptake for whole tumour TACs.

Table 3 Bias and uncertainty results from MC simulations for 1C2K and 2C4K ground truths.

Correlation of kinetic and static parameters

18F-Fluciclovine uptake was shown to peak in malignant lesions during the 5–10 min interval post injection; SUVmax and SUVpeak were significantly higher (p < 0.05) during this time frame than any other. The uptake in malignant breast cancer lesions across varying time intervals is graphically depicted in Fig. 3a. When these data were broken down by tumour receptor subtype, the same trend was observed, as shown in Fig. 3b. As a result, any further static analysis was carried out using the uptake in the 5–10 min interval.

Fig. 3: SUVs of 18F-fluciclovine in breast tumours at varying time points.
figure 3

a SUVmax and SUVpeak uptake of 18F-fluciclovine, b SUVmax uptake broken down by receptor subtype. Error bars represent the standard deviation from the mean value.

Figure 4 shows the correlation of SUVmax against kinetic parameters K1 and K1/k2 in all malignant tumours. Moderate to strong positive correlations were observed for both, with Pearson’s correlation R values of 0.65 and 0.76, respectively [23]. The resulting correlation demonstrates good equivalence between static and kinetic parameters for this tracer. In order to study and better understand the underlying differences between them, it was useful to analyse relationships between both static and kinetic values with respect to clinical variables.

Fig. 4: Correlations of SUVmax against kinetic parameters for 18F-fluciclovine in breast tumours.
figure 4

a K1 and b  volume of distribution (K1/k2) plotted against SUVmax. Goodness-of-fit lines are displayed alongside the corresponding goodness of fit value, R.

Correlation of kinetic and static parameters with relation to clinical variables

SUV and kinetics by receptor subtype

Tumour receptor status was categorised into three groups: oestrogen receptor positive only (ER+ and HER2−), human epidermal growth factor receptor positive (HER2+) and TN. There were no significant differences in uptake or kinetics between any of the receptor subtypes (Fig. 5).

Fig. 5: 18F-fluciclovine uptake across tumour receptor subtypes.
figure 5

a SUVmax, b SUVpeak, c K1 and d volume of distribution plotted for oestrogen receptor positive only (ER+), human epidermal growth factor receptor positive (HER2+) and triple-negative (TN) hormone receptor subtypes.

SUV and kinetics by tumour grade, Ki-67 and NLR

Histologic examination of biopsy samples was performed in order to assess the Nottingham grade of each tumour (grade 1, 2 or 3). No significant differences in SUV or kinetics with grade were observed. SUVmax values of grade 1, 2 and 3 tumours ranged from 4.2 to 17.6, 3.3 to 12.9 and 4.7 to 12.0, respectively. A trend toward the elevated volume of distribution and SUVmax was observed in grade 1 tumours (see Supplementary Fig. 3).

No correlations were seen between the static and kinetic 18F-fluciclovine parameters and mean Ki-67 or NLR.

SUV and kinetic parameters for patients on and off metformin

Four study patients (10%) were taking metformin for the treatment of type 2 diabetes. In patients taking metformin, SUVpeak was greater (SUVpeak, 8.5 ± 1.0 versus 5.7 ± 2.6; p = 0.04) and a similar trend was observed for SUVmax (p = 0.07) and the kinetic variables K1 (p = 0.05) and volume of distribution (p = 0.06). Plots of static and kinetic parameters for patients on and off metformin are shown in Fig. 6.

Fig. 6: 18F-fluciclovine uptake in patients taking metformin.
figure 6

Mean values of a SUVmax, b SUVpeakc K1 and d volume of distribution plotted for patients who were on and off metformin. Error bars represent the standard deviation from the mean.

Discussion

In our analysis, kinetic modelling of the dynamic PET images demonstrated that 18F-fluciclovine uptake in breast cancer is best described by a reversible one-tissue compartment model. This concurred with the kinetic analysis of 18F-fluciclovine uptake in prostate cancer reported by Sorensen et al. in 2013 [6]. The reversible nature of 18F-fluciclovine in breast cancer may affect quantitation and lesion detection at later time points after tracer injection. This must be taken into consideration when setting up imaging protocols, where a short uptake time would seem optimal, and also aligns with the approach currently adopted in 18F-fluciclovine imaging of recurrent prostate cancer [24, 25]. The peak uptake of this tracer in breast cancer was observed to be at 5–10 min post administration, which is similar to previous studies in both breast [8, 9] and prostate cancer [6]. This suggests that a similar clinical imaging approach to that of recurrent prostate cancer imaging would be appropriate.

Our study showed that there was no association between the surrogate markers of prognosis, Ki-67, grade and NLR. Also, there was no clear evidence that 18F-fluciclovine uptake is dependent on tumour receptor status. A slight trend toward an increase in uptake was seen in triple-negative breast cancers compared to other hormone receptor types (not significant), as reported in a smaller study by Tade et al. [8]. A possible explanation is that the transcription factor, Myc, is disproportionally expressed in triple-negative breast cancer and its expression has been associated with tumour cell dependence on glutamine metabolism [26]. In addition, a confounding factor could have been the cellular density. Previous work using mammography has shown differences in cellular density between breast tumour subtypes [27], and tumours with a higher cellular density would have greater PET tracer uptake [28].

Good correlations were seen between the measured static and kinetic parameters within this study and similar trends were observed between tumour characteristics and 18F-fluciclovine uptake for both static and kinetic parameters. This would indicate that detailed kinetic analysis for routine clinical purposes does not provide any additional information on the uptake of 18F-fluciclovine in breast cancer. However, the kinetic analysis may still have a role in the assessment of subtle differences in 18F-fluciclovine uptake, for example, in the use of paired imaging in pharmacodynamic drug trials, a context where kinetic analysis can add value [29].

The uptake of amino acids, in particular glutamine, is an important contributor to the carbon pool necessary for anabolic metabolism and hence cell proliferation. Hence, it was unexpected that no correlation between tumour grade or Ki-67 and uptake of 18F-fluciclovine was observed in this study, in contrast to FDG uptake in breast cancer that has shown a positive correlation with grade [30, 31].

We previously showed in a pharmacodynamic ‘window of opportunity’ study that a short course of metformin led to an increase in FDG flux on kinetic analysis of PET-CT when comparing imaging pre- and post treatment [29]. Metformin inhibits complex 1 of the mitochondrial electron transport chain, disrupting the tricarboxylic acid cycle and hence the ability of tumour cells to funnel carbon from glucose toward the synthesis of macromolecules necessary for cell proliferation. In response to mitochondrial dysfunction, tumour cells may switch to amino acids as carbon sources for these anabolic processes [32]. Hence, the observation that tumours had a greater degree of 18F-fluciclovine uptake in patients taking metformin was consistent with these preclinical observations. However, this analysis was very much limited by the small number of patients taking metformin and to confirm this finding an appropriately controlled and better powered study in metformin patients would be necessary.

Future work could include investigating the impact of motion correction or improved PET reconstruction algorithms on the breast tumour PET parameters. By utilising these new technologies, it may also enable the assessment of 18F-fluciclovine uptake within the lymph nodes.

To our knowledge, this is the largest clinical study to date that assesses the uptake of 18F-fluciclovine in primary breast cancer and the first to assess kinetic parameters in this context. This study showed promising results in the use of 18F-fluciclovine in the imaging of primary breast cancer across all receptor subtypes and tumour grades. The observation that metformin used by patients was associated with increased uptake of 18F-fluciclovine suggests the potential for this tracer to describe the metabolic response to anti-mitochondrial cancer therapies, a number of which are in development.