Abstract
To report the visual and refractive outcomes of new aspheric hydrophobic acrylic monofocal intraocular lens (IOL). Retrospective case series. This study included eyes of patients who underwent routine cataract surgery for uncomplicated age-related cataract with implantation of a Aktis SP (NS-60YG; Nidek Co. Ltd., Japan) IOL and attended regular follow ups at 1 week, 1 month, 3 months, and 12 months. At each post-operative visit, ophthalmological evaluation included measurement Uncorrected (UCVA) and Best corrected visual acuity (BCVA), contrast sensitivity, posterior capsular opacification (PCO), optical aberrations, analysis of point spread function (PSF) and modulation transfer function (MTF). The study included 2102 eyes of 1358 patients aged 45 to 75 years (mean age 62.6 years ± 5.6 SD). The mean preoperative BCVA was 0.56 ± 0.26 logMAR. At 1 year follow up, the mean postoperative UCVA and BCVA were 0.11 ± 0.09 and 0.02 ± 0.03 logMAR, respectively. At the end of 6 months, around 1487 (93%) eyes had BCVA of 20/20 and better than 20/30 in 100% of the eyes. Mild posterior capsule opacification (PCO) was observed in 56 patients, but none required Nd YAG laser capsulotomy. There was reduction in ocular spherical aberration and Higher order aberrations (HOAs) as compared to pre operative. This explains better contrast sensitivity obtained by MTF and PSF values. The study shows that the Aktis SP IOL is safe, effective, and stable lens that could be inserted through 2.2 mm incision with satisfactory visual and refractive outcomes, even in late post-operative period.
Similar content being viewed by others
Introduction
A paradigm shift has been seen in the outcomes of cataract surgery over years1. The credit not only goes to improved cataract surgery techniques and technologies like microincision phacoemulsification and femtosecond laser assisted cataract surgery, but also to marked improvement in intraocular lenses (IOLs)2,3,4,5. The first IOL was implanted in 1949 by Sir Harold Ridley. Since then IOLs have undergone revolutionary changes. Monofocal IOLs, which restore unaided visual acuity for far vision, are currently the most commonly used6. However, these patients need reading glasses to compensate for the loss of ability to see near distances. In the last one-decade, we have witnessed a variety of newer concept IOLs like multifocal IOLs, trifocal IOLs, extended depth of focus lenses7,8,9,10. Diffractive and refractive designs IOLs are also used. Newer technologies like enlighten optical technology and convolution processes have been developed to reduce the light loss and sharper vision in trifocal IOLs11. Most of these advances in IOL technology aim at providing good vision at all distances that is near, intermediate and far. All these lenses have some advantages and also have their own set of problems. The problem of glare and haloes makes these multifocal IOLs not suitable for many patients7,8,9,10. The other limitation of these IOLs is that they are not suitable in patients with diabetic retinopathy, glaucoma and poor ocular surface. The steep cost of these premium IOLs must also be taken into consideration. These limitations make trifocal lenses not so commonly used in comparison to monofocal IOLs. In monofocals, the neuroadaptation is better and patients have lower rate of visual disturbances12. In Indian scenario, monofocal IOLs still represent the most used ones in the current surgical practice. The previous generation of monofocal IOLs have been reported to have higher rates of posterior chamber opacification (PCO)13. Newer monofocal IOL design, larger optic zones and square edged optic design has significantly improved the outcomes of cataract surgery and reduced the PCO14,15,16. Nowadays, the aim of IOL implantation is not only to attain post-operative emmetropia but also to improve factors like optical quality and contrast sensitivity. An in vitro experimental study of NS-60YG (NIDEK) IOL demonstrated that this IOL showed fewer glistenings and long-term stability with no signs of deterioration due to ageing17, but clinical evidence is not yet available. The current study aims to evaluate the visual and refractive outcomes of newer aspheric monofocal IOL Aktis SP (NS-60YG; Nidek Co. Ltd., Japan).
Materials and methods
This was a retrospective non-comparative chart review including patients who were scheduled to undergo routine cataract surgery with implantation of Aktis SP monofocal IOL implantation between July 2017 and October 2019. All the study procedures and surgeries were performed at a single centre (Bharti eye hospital and foundation). The study conduct adhered to the tenets of Declaration of Helsinki, and the Bharti eye foundation ethics board committee reviewed and approved the study. The patients were selected from the consecutive cases from the clinic population who were eligible for routine phacoemulsification cataract surgery and IOL implantation. Subjects were excluded from the study if they were unable to comprehend written or spoken language or unable to give informed consent, if they had any ocular disease other than cataract and previous ocular surgery or inflammation. Other exclusion criteria include presence of amblyopia, previous refractive surgery, significant ocular surface disease, glaucoma, existence of corneal, retina or optic nerve disease, axial lengths of < 22 or > 26 mm, astigmatism of 1.00 D or higher. Written informed consent to participate in the study was obtained from all subjects7.
Intraocular lens
The study IOL was the Aktis SP (NS-60YG; Nidek Co. Ltd., Japan), which is a one-piece monofocal hydrophobic acrylic IOLs with modified C-loop haptics, 6 mm optic diameter and a total diameter of 13 mm (Fig. 1). The IOL is made of copolymer of n-butyl acrylate, n-butyl methacrylate and phenoxyethyl acrylate with asperitic optic side surface. The lens is injected into the eye using the preloaded IOL injection system which enables 2.2 mm in-the-bag implantation. It has a continuous 360° square edge profile which intended to help provide a barrier against cell migration. The 90° haptic design enlarges the contact area with the capsular bag resulting in a stable, well-centered IOL implantation while the asperitic optic side surface reduces intraocular reflection and optic edge glare. The IOL has a blast finishing on the haptic surface which reduces adherence to the optic surface during lens folding and improves the visibility of the haptic when the lens is loaded into the cartridge18.
Patient assessment
All subjects underwent a standardized pre-operative ophthalmic examination including measurements of uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA) for distance, manifest refraction, slit-lamp examination and biomicroscopy, Goldmann applanation tonometry, optical biometry, keratometry, endothelial cell count (CEM 530, Nidek Co. Ltd., Japan) and retinal evaluation under pupil dilation. The patients were evaluated post-operatively at 1 week, 1 month, 3 months, 6 months and 12 months after surgery. The main outcome measure was distance visual acuity. The CDVA was evaluated at all postoperative visits. Distance vision was measured with logMAR notation using the Early Treatment Diabetic Retinopathy Study (ETDRS) charts (ETDRS; Vector Vision, Ltd, Greenville, OH, USA) at 4 m. The visual acuity testing was done under photopic conditions (85 candelas [cd]/m2) and at 100% contrast. Other outcome measures were optical performance of IOL. The optical quality of IOL was assessed by modulation transfer function (MTF) and the point-spread function (PSF), using a corneal analyzer system (OPD-Scan III, Nidek Co., Ltd.) The software obtains PSF, expressed as the Strehl ratio, which is the ratio between the intensity of the real PSF and the intensity of the diffraction-limited PSF. The assessment was done at 3.0 mm and 5.0 mm pupil diameters (PD). The PSF describes the quality response of an imaging system and is expressed by the Strehl ratio, with 1 indicating a perfect optical system. The mean MTF values were calculated in a logarithmic plot and log base 10 contrast sensitivity values were used to construct a graph for each spatial frequency tested. Patients also underwent wavefront aberrometry (OPD scan III, NIDEK, Japan) for evaluation of wavefront total spherical aberration and higher order aberrations (HOAs). Optical biometry was done on AL scan (NIDEK, Japan). SRK/T formula was used to calculate the IOL power. Company-labeled A-constant was 119.6. All patients underwent uneventful phacoemulsification. Cataract surgery with implantation of Aktis SP hydrophobic acrylic monofocal IOL by our experienced surgeons. A standard sutureless microincision (2.2 mm) phacoemulsification technique was used. All surgeries were performed on Infiniti Vision system (Alcon, USA). The anterior capsulorhexis of approximately 5.0 mm diameter was created and the IOL was implanted in the capsular bag with manufacturer’s recommended IOL loading and injection technique. Postoperatively, topical therapy included a combination of antibiotics and steroidal agents. The eyes were targeted for emmetropia.
Statistical analysis
Statistical analyses were performed using SPSS statistics for Windows (IBM SPSS Statistics for Windows, Version 19.0., Armonk, NY). Normality was checked using the Kolmogorov–Smirnov test. Statistically significant differences were determined using the Student t test and paired-sample t test. Statistical significance was set at P < 0.05.
Results
Total 2340 eyes of 1553 patient underwent cataract surgery with Aktis SP NS-60YG IOL implantation during the study period. Of these, 2102 eyes of 1358 patients were included in the study. 238 eyes were excluded from the review because of associated ocular pathology other than cataract. The most common factors that were responsible for exclusion of these eyes were diabetic retinopathy, glaucoma, Age related macular degeneration, amblyopia and severe dry eye. Four eyes of 4 patients required additional IOL repositioning in the post-operative period and were excluded from the study. All patients completed all follow-up examinations up to 12 months postoperatively. The patients were aged 45 to 75 years (mean age 62.6 years ± 5.6 SD). Patient characteristics and preoperative data are shown in Table 1.
The mean UCVA and BCVA over time at all post-operative visits are shown in Fig. 2. On the first postoperative day, a CDVA of 20/20 was achieved in 1325 (83%) eyes. At the end of 6 months, around 1487 (93%) eyes had BCVA was 20/20 and better than 20/30 in 100% of the patients (Fig. 3). The post-operative mean SE and the mean refractive astigmatism were − 0.25 ± 0.39 D and − 0.46 ± 0.30D, respectively, at 1 year follow up. During the entire follow-up period, there were no significant fluctuations in the postoperative refraction. The spherical equivalent was within ± 0.5 D in 76% and ± 1.0 D in 90% eyes at 12 months postoperatively (Fig. 4). There was a mean reduction of 0.87% endothelial cell loss at 12 months post-operative period. The mean corneal endothelial cell density preoperatively and at 12 months postoperatively was 2756 ± 176 per mm2 and 2516 ± 207 per mm2 169, respectively. At the end of 12 months, none of the cases had required laser capsulotomy.
Though mild posterior capsule opacification was observed in 56 patients on subjective evaluation, but the visual acuity was not affected. The mean BCVA among these 56 eyes were 0.029 ± 0.02 logMAR. In our cohort, 1852 eyes have completed 3 years follow up and 148 of these eyes showed mild posterior capsular opacification on subjective evaluation but there was no decrease in visual acuity The mean BCVA among these 1852 eyes were 0.023 ± 0.02 logMAR.
Figure 5a,b shows the MTF function curves at different spatial frequencies with a 3.0 mm and 5.0 mm pupil diameter at 12 months post-operative respectively. The Strehl ratio values with a 3.0 mm and 5.0 mm PD at 1 year post-operative follow-up were 0.84 and 0.79 respectively. The pre and post-operative values of spherical aberration and HOA for 3 mm pupil and 5 mm is shown in Table 2. The postoperative wavefront analyses, including the mean HOA values and spherical aberration at 1 year visits for the two groups were found to be statistically significant than baseline. None of the patients complained about photopsia while glistenings and surface light scattering were not observed in any eye.
During the entire follow-up period, there were no other significant intraoperative or postoperative complications such as intraocular pressure spikes, IOL decentration, tilting or dislocation, prolonged corneal edema or inflammations or any infective events. There was no secondary surgical intervention in the study group.
Discussion
In this study, we analysed the visual outcomes and clinical performance of a hydrophobic acrylic monofocal IOL-NS-60YG. We found that this IOL was safe and effective with excellent postoperative vision, thereby providing satisfactory visual and refractive outcomes even in late postoperative period.
To our knowledge, this is first study to report the clinical outcomes in a cohort that had implantation of Aktis SP, NS-60YG IOL. Our findings showed that there was improvement in distance vision from 0.56 ± 0.12 to 0.22 ± 0.14 logMAR at 1 year post-op. The BCVA of the 637 eyes who were followed uptil 2 years was 0.24 ± 0.34 logMAR. These results are in agreement with findings obtained in previous studies with different IOL models14,16,19,20,21. We observed the post-operative mean SE to be -0.25 ± 0.39 D at 1 year follow up. Similar outcome has been observed in previous studies with different IOLs14,16,24. The mean refractive astigmatism of 0.25 ± 0.39 found in our study at 1 year follow up was too comparable to previous studies using monofocal IOLs14,22.
Technological advancements have brought about the use of acrylic made soft foldable inert materials which resulted in the development of aspheric IOLs to compensate for the corneal aberrations. Obtaining a satisfying refraction after cataract surgery is no longer the only goal of these new generation IOLs, but to also enhance the visual performance by improvement in contrast sensitivity function. Our study showed that the contrast sensitivity in terms of MTF and Strehl values achieved near normal values postoperatively, which has been previously documented in other studies with monofcal IOLs as well23.
In our study, we also evaluated spherical aberration and HOAs at 5 and 6 mm pupil size. The HOAs reflect the optical quality of the human eye after correction for sphere and cylinder. Data in our study showed that the wavefront analysis at all post-operative visits were found to be statistically significant than baseline, and implantation of an aspheric IOL leads to reduction in HOAs. As compared to previous studies, we found a higher amount of spherical aberration compared with that analyzed other types of aspheric IOLs, which have residual negative spherical aberration24.
The optics quality of the IOL was better with small pupils due to low aberration effect. This was seen in the graphs in which the curve was close to the diffraction curve, similar to what was described in previous studies25. One of the most significant complications of cataract surgery is PCO. In our study, 56 eyes (2.6%) had mild PCO at 1 year postoperatively, with none of the cases had requiring laser capsulotomy. The visual acuity of these 56 eyes were 0.029 ± 0.02 logMAR. Even among the 1852 eyes completing 2 years follow up, 148 of these eyes (7.99%) showed mild PCO on subjective evaluation but there was no decrease in visual acuity that could have necessitated laser capsulotomy. Similar rates have been observed in other studies26,27,28,29. Its known that IOLs with hydrophobic material and a sharp optic edge provide lower incidences of PCO30,31,32,33. The IOL in our study also had a 360° square edge, which protects against migration of the lens epithelial cells into the back of the optic and the haptic junction, minimizing the risk of PCO. There is double-polymerization of monomers in the IOL, which decreases voids in the IOL structure resulting in a stable polymer. This unique structural architecture inhibits water components from coalescing and reduces the chances of glistening and whitening and gives the IOL long-term stability. An experimental study study of NS-60YG IOL demonstrated that this IOL showed fewer glistenings and long-term stability with no signs of deterioration due to ageing. The results of that study evaluated the stability of IOL material simulating 20 years of ageing after implantation in an eye17.
To the best of our knowledge, this is a first manuscript which evaluates visual and refractive outcome of this hydrophobic aspheric monofocal IOL. The effectiveness of an IOL can be estimated by the visual outcomes and performance over a long follow-up period and this study has showed that Aktis SP NS-60YG IOL has good visual and optical quality even in the postoperative period. Significant contrast sensitivity enhancement and reduced spherical aberration was also seen.
Data availability
The datasets used and/or analysed during the current study available from the corresponding author on reasonable request.
References
Olson, R. J. Cataract surgery from 1918 to the present and future-just imagine!. Am. J. Ophthalmol. 185, 10–13 (2018).
Vasavada, V., Vasavada, V., Raj, S. M. & Vasavada, A. R. Intraoperative performance and postoperative outcomes of microcoaxial phacoemulsification; observational study. J. Cataract. Refract. Surg. 3, 1019–1024 (2007).
Roberts, T. V., Lawless, M., Bali, S. J., Hodge, C. & Sutton, G. Surgical outcomes and safety of femtosecond laser cataract surgery; a prospective study of 1500 consecutive cases. Ophthalmology 120, 227–233 (2013).
Kendall, E. D. et al. Femtosecond laser—assisted cataract surgery. J. Cataract. Refract. Surg. 39, 1753–1763 (2013).
Moshirfar, M., Churgin, D. S. & Hsu, M. Femtosecond laser-assisted cataract surgery: A current review. Middle East Afr. J. Ophthalmol. 18, 285–291 (2011).
Carson, D. et al. Optical bench performance of AcrySof((R)) IQ ReSTOR((R)), AT LISA((R)) tri, and FineVision((R)) intraocular lenses. Clin. Ophthalmol. 8, 2105–2113 (2014).
Bhupesh, S., Sharma, S., Dadia, S., Bharti, N. & Bharti, S. Comparative evaluation of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and an extended depth of focus intraocular lens. Eye Contact. Lens. 46(5), 314–318 (2020).
Alio, J. L. et al. Comparison of a new refractive multifocal intraocular lens with an inferior segmental near add and a diffractive multifocal intraocular lens. Ophthalmology 119, 555–563 (2012).
de Vries, N. E. et al. Dissatisfaction after implantation of multifocal intraocular lenses. J. Cataract. Refract. Surg. 37(5), 859–865 (2011).
Carballo-Alvarez, J., Vazquez-Molini, J. M. & Sanz-Fernandez, J. C. Visual outcomes after bilateral trifocal diffractive intraocular lens implantation. BMC Ophthalmol. 14, 26 (2015).
Sudhir, R. R., Dey, A., Bhattacharrya, S. & Bahulayan, A. AcrySof IQ PanOptix intraocular lens versus extended depth of focus intraocular lens and trifocal intraocular lens: A clinical overview. Asia Pac. J. Ophthalmol. (Phila). 8(4), 335–349 (2019).
de Silva, S. R., Evans, J. R., Kirthi, V., Ziaei, M. & Leyland, M. Multifocal versus monofocal intraocular lenses after cataract extraction. Cochrane Database Syst. Rev. 12, 169 (2016).
Prakash, P., Kasaby, H. E., Aggarwal, R. K. & Humfrey, S. Microincision bimanual phacoemulsification and Thinoptx implantation through a 1.70 mm incision. Eye 21, 177–182 (2007).
Alio, J. L., Rodriguez-Prats, J. L., Vianello, A. & Galal, A. Visual outcome of microincision cataract surgery with implantation of an Acri. Smart Lens. J Cataract. Refract. Surg. 31, 1549–1556 (2005).
Alio, J. L., Pinero, D. P., Ortiz, D. & Montalban, R. Clinical outcomes and postoperative intraocular optical quality with a microincision aberration-free aspheric intraocular lens. J. Cataract. Refract. Surg. 35, 1548–1554 (2009).
Can, I., Takmaz, T., Bayhan, H. A. & Bostancı, C. B. Aspheric microincision intraocular lens implantation with biaxial microincision cataract surgery: Efficacy and reliability. J. Cataract. Refract. Surg. 36, 1905–1911 (2010).
Kawai, K. An evaluation of glistening and stability of intraocular lens material manufactured by different methods. Eur. J. Ophthalmol. 30, 1120672120902038 (2020).
Tinted and Aspheric Single-piece IOL Aktis SP https://www.nidekintl.com/product/ophthaloptom/surgical/sur_intraocular/aktis_sp.html
von Sonnleithner, C. et al. Clinical results and higher-order aberrations after 14-mm biaxial cataract surgery and implantation of a new aspheric intraocular lens. Ophthalm. Res. 53, 8–14 (2015).
Toygar, B., Yabas Kiziloglu, O., Toygar, O. & Hacimustafaoglu, A. M. Early clinical outcome with a new monofocal microincision intraocular lens. Int. Ophthalmol. 36(5), 657–664. https://doi.org/10.1007/s10792-016-0178-7 (2016).
Nanavaty, M. A., Spalton, D. J., Gala, K. B., Dhital, A. & Boyce, J. Fellow-eye comparison of posterior capsule opacification between 2 aspheric microincision intraocular lenses. J. Cataract. Refract. Surg. 39, 705–711 (2013).
Wilczynski, M. et al. Comparison of surgically induced astigmatism after coaxial phacoemulsification through 1.8 mm microincision and bimanual phacoemulsification through 1.7 mm microincision. J. Cataract. Refract. Surg. 35, 1563–1569 (2009).
Son, H. S. et al. In vitro optical quality measurements of three intraocular lens models having identical platform. BMC Ophthalmol. 17(1), 108 (2017).
Caporossi, A., Martone, G., Casprini, F. & Rapisarda, L. Prospective randomized study of clinical performance of 3 aspheric and 2 spherical intraocular lenses in 250 eyes. J. Refract. Surg. 23, 639–648 (2007).
Kawamorita, T. & Uozato, H. Modulation transfer function and pupil size in multifocal and monofocal intraocular lenses in vitro. J. Cataract. Refract. Surg 31, 2379–2385 (2005).
Yadav, S. et al. Comparison of visual performance and after cataract formation between two monofocal aspheric intraocular lenses following phacoemulsification for senile cataract: A randomized controlled study. Indian J. Ophthalmol. 65(12), 1445–1449 (2017).
Awasthi, N., Guo, S. & Wagner, B. J. Posterior capsular opacification: A problem reduced but not yet eradicated. Arch. Ophthalmol. 127, 555–562 (2009).
Bender, L. E. et al. Effect of 1-piece and 3-piece AcrySof intraocular lenses on the development of posterior capsule opacification after cataract surgery. Cataract. Refract. Surg. 30, 786–789 (2004).
Ursell, P. G. et al. Relationship between intraocular lens biomaterials and posterior capsule opacification. J. Cataract. Refract. Surg. 24(352), 60 (1998).
Nanavaty, M. A., Spalton, D. J., Boyce, J., Brain, A. & Marshall, J. Edge profile of commercially available square-edged intraocular lenses. J. Cataract. Refract. Surg. 34, 677–686 (2008).
Apple, D. J. et al. Eradication of posterior capsule opacification: Documentation of a marked decrease in Nd: YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem. Ophthalmology 108, 505–518 (2001).
Buehl, W. et al. Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification. J. Cataract. Refract. Surg. 31, 954–961 (2005).
Hayashi, K. & Hayashi, H. Posterior capsule opacification in the presence of an intraocular lens with a sharp versus rounded optic edge. Ophthalmology 112, 1550–1556 (2005).
Author information
Authors and Affiliations
Contributions
B.S. and S.S. wrote the main manuscript. N.B. and D.S. were involved in data collection and preparation of figures and tables. D.P. and S.B. reviewed the manuscript
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Singh, B., Sharma, S., Bharti, N. et al. Visual and refractive outcomes of new intraocular lens implantation after cataract surgery. Sci Rep 12, 14100 (2022). https://doi.org/10.1038/s41598-022-14315-6
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-022-14315-6